Portable corrosion monitoring instruments
Products list- High Precision Electrical Resistance Probe Corrosion Monitoring System
- LPR Probe corrosion monitoring system
- Two inch access fitting assembly
- Coupon corrosion monitoring system
- Integrated online corrosion monitoring system
- Retrievers & Service valves
- Corrosion and protection management system
- Automatic cleaning and maintaining system for pH electrode
- Automatic control of injection system for overhead
- Online High Temperature Ultrasonic Thickness Measurement system
- Online Electric Field Matrix Thickness Measurement system
- Portable corrosion monitoring instruments
ZKW280 Stray Current Measurer
Given the irregularity and fast change of stray current, high-precision and high-speed analog-to-digital converter and high-capacity data storage and single chip processor system are used to collect, convert, process and store analog potential signal at a high speed. The main unit of the instrument includes a clock circuit, to control measurement time; a dot-matrix LCD displays menu and data, with the measurement process controlled by single chip processor. Subject to repeated technique arguments and a large number of experimental studies, KW280 stray current measurer has been developed into a high-precision intelligent instrument, with the advantages of easy operation, fast measurement, and easy-to-understand result. Data variation can be observed directly from the LCD, and the data regulation can also be carefully analyzed through what the software displays. The measurer has the function of multi-point continuous measurement.
The instrument is applicable to real-time monitoring for spray current of urban and rural underground transmission pipeline and ships
Technical Index:
·Measurement range: |
±14V (DC) -10Vp-p (AC) |
·Measurement temperature: | -32~+158.0 °F or 0~+70.0 °C |
·Accuracy: | Within ±0.1% of measurement range |
·Sensitivity: | Within ±0.1% of measurement range |
·Repeatability: | Within ±0.05% of measurement range |
·Response time: | 0.2 ms (for over 90% response) |
·Input impedance: | 1013Ω |
·Stored data amount: | 30000 set/channel (simultaneous measurement for dual channel) |
·Transmission type: | USB2.0 |
·Distance between sensor and measurer: |
DC test-------------- Longest distance 25 m (82 ft) AC test-------------- Longest distance 10 m (32.8 ft) |
·Power requirements: |
Battery specification (NiMH)------------ 4500mAH (5-battery series connection) Battery specification (Lithium)---------- 17AH (single) |
·Test leads requirement: | Single conductor shielded leads ¢1.0mm; |
Standard Configuration:
NO. | Name | Type | Qty. |
1 | Main unit of stray current measurer | ZKW280/281/282 | 1 Set |
2 | Copper sulphate electrode | GY250 | 2 PCS |
3 | Checker | ZKW230/2.5V | 1 PCS |
4 | Charger | GY450 | 1 PCS |
5 | Test cable | ZKW250 | 2 PCS |
6 | Communication cable (USB dual male) | GY560 | 2 PCS |
7 | Test pen | ZKW251 | 2 PCS |
8 | Test fish clip | ZKW252 | 2 PCS |
9 | Connecting line of checker | ZKW253/254 | 1 PCS |
10 | Instruction manual | ZKW290/291 | PCS |
11 | CD | ZKW291/292 | Set |
Packing Description:
Shell: NEMA 4X polycarbonate plate, for general purpose; |
External dimension:3.75 inch wide×3.75 inch high×2.32 inch thick (95 mm wide×95 mm high×60 mm thick) |
Net weight: 5.6kg |