ZKW880 Corrosion Rate Measurer
The corrosion rate measurer adopts the method combining linear polarization, weak polarization and AC impedance to measure corrosion rate. For the polarization resistance technique, Stern formula is used to estimate corrosion current density Icorr.
Icorr=B/Rp
Based on polarization resistance measured by linear polarization technique, the polarization technique applies weak polarization to measured electrode, and Tafel constant can be calculated by the polarization current in the weak polarization region, and then the metal corrosion rate can be measured. Weak polarization technique not only eliminates substantial theoretical errors of linear polarization caused by Tafel constant estimation, but also eradicates damage to the electrode face caused by the application of the polarization curve method, i.e. Tafel line extrapolation method. AC impedance method is to apply weak high frequency sine wave signal to corrosion system. The high frequency signal can pass through the interface capacitance between metal and medium, and completely acts on dielectric resistance, and therefore the dielectric resistance of the system can be measured. The polarization resistance calculated by stationary linear polarization measurement minus the dielectric resistance is the actual polarization resistance of the corrosion system, and then the corrosion rate can be accurately measured.
·Applicable to fast measurement of corrosion rate in the industrial production site
·Research on assessment of laboratory metal corrosion rate
·Corrosion inhibitor screening, performance evaluation of water quality stabilizer and coatings, etc.
·Qualitative observation of corrosion trend and reaching a quantitative result
Technical Index
(1) Main Unit of Instrument:
Operating temperature | 0-40 ℃ |
Relative humidity | ≤80%RH |
Measurement range of Ecorr | ±800mV |
Measurement range of corrosion rate |
4×10-4~10mm/a (electrode area: 1cm2) 1×10-4~2.5mm/a (electrode area: 4cm2) |
Measurement range of polarization resistance RP | 20Ω~500KΩ |
Measurement range of dielectric resistance RS | 10Ω~100 KΩ |
Single measurement time | 2 min |
Fixed-time automatic measurement interval | 10—99 min |
Data storage capacity | 2000 Group |
Measurement error compared with stimulation system | ≤3% |
(2) Standard Accessories Parameters:
Nylon electrochemical electrode holder | Technique specification | |
Temperature-resistance | 80 ℃ | |
Pressure resistance | Normal pressure | |
Length | 80 mm | |
Material | Nylon | |
Cylindrical electrochemical electrode | Material | Carbon steel, stainless steel, brass, etc. |
Electrode area | 4 cm2 | |
Female thread | M3 |
Configuration Information:
NO. | Name | Type | Qty. |
1 | Main unit of corrosion rate measurer | ZKW880 | 1 |
2 | Nylon electrochemical electrode holder | ZKW820-M3-L80 | 2 |
3 | Cylindrical electrochemical electrode | ZK8290- Material -S4 | 6 |
4 | Checker | ZK8300/10K | 1 |
5 | Charger (12V-4A) | GY450 | 1 |
6 | Power cords | GY570 | 1 |
7 | Test leads | ZKW851 | 1 |
8 | Communication line | ZKW852 (aviation plug to DB9 serial port ) | 1 |
9 | Instruction manual | ZKW890 | 1 |
10 | CD | ZKW891 | 1 |
Packing Description:
Equipment net weight: |
Equipment gross weight: |
Packing dimensions: 90×450×305 mm |
Wrap: Cardboard boxes for outer packing and aluminum boxes for inner packing. |